Data from the manufacturer's datasheet • iiM GmbH Product No.: 402.0013.01

VisioCablePro® TLD – cable lay length measurement without removing the jacket

Twist / Lay / Pitch Length Detector • lay 10–800 mm, LV212 and LV122

VisioCablePro® TLD measures the lay length of conductors in jacketed cables without removing the jacket. Traditional methods require stripping the jacket and untwisting the conductors, which alters the sample and prevents accurate measurement. Measurement is fully automatic: after a single click, the sensor travels along the sample by itself, and the results can be exported to a PC. The device measures in accordance with LV212 and LV122.

📸 Photos from the datasheet (click to enlarge):

Key features of the TLD:

🧵 No jacket removal

Lay length is measured on the jacketed cable – the sample is not untwisted or stripped, so the result is accurate.

⚙️ Fully automatic

One click starts the measurement – the sensor travels along the sample by itself. A slower pass gives a more accurate result.

📐 LV212 and LV122

Measurement compliant with LV212 and LV122, 1 mm accuracy, lay length from 10 to 800 mm.

💾 Result export

Number of twists, measured length, sensor travel, minimum, maximum and average lay – saved to a text file via a PC.

Technical data (per the TLD datasheet):

Product number402.0013.01
Dimensions (W × L × H)1320 × 420 × 480 mm
Weight43 kg
Power supply100–240 V, 50–60 Hz
Powermax. 100 W
MaterialAluminium, stainless steel, PVC
Measuring accuracy1 mm
StandardsLV212, LV122
Measurable lay lengthmin. 10 – max. 800 mm (at the standard measuring length; others on request after sending samples)
Measuring length800 mm (other on request)
Sample outer diametermin. 2 mm (thin cables require an adapter; others on request after sending samples)
Sensor speedSet in the configuration file – the slower, the more accurate
ResultsNumber of twists, measured section, sensor travel, minimum and maximum lay, average lay
CalibrationWith a master sample

When to choose the TLD?

When your customer requires conductor lay length measurement per LV212 or LV122 and you want to measure on the finished jacketed cable without untwisting the sample by hand. Insulation and jacket geometry on the cross-section of the same cable can be measured on the VCPX5 or VCPLab.

Frequently asked questions (FAQ):

What does the VisioCablePro® TLD measure?

The lay length (twist / lay / pitch length) of conductors in jacketed cables, without removing the jacket: number of twists, minimum, maximum and average lay.

What lay length range does the TLD measure?

From 10 to 800 mm at the standard measuring length of 800 mm, with 1 mm accuracy. Other ranges are possible on request after sending samples.

Which cables can be measured on the TLD?

Jacketed cables with an outer diameter from 2 mm; thin cables require a mounting adapter.

VisioCablePro TLD Lay length measurement Lay length LV212 LV122