1. Crimp height – the basic check
The simplest and most common measurement. The crimp height on the conductor (and separately on the insulation) is measured with a crimp micrometer or a bench height gauge. The nominal value and tolerance for a given wire cross-section are specified by the terminal manufacturer. The measurement is taken:
- at every applicator set-up (first piece),
- after changing the terminal reel or the wire batch,
- periodically during production, according to the control plan.
2. Pull test
The wire with the crimped terminal is pulled in a tester at a constant speed, and the force at which the connection fails is measured. Minimum values for each cross-section are given by standards (including IEC 60352-2) and customer requirements. The test is destructive, so it is carried out on samples – usually at set-up and periodically. Testers with a printout or report make it easier to document the results.
3. Cross-section micrograph
The crimp is cut, ground and examined under a microscope. The cross-section shows what cannot be seen from the outside: crimp fill, symmetry, the position of burrs, cracks and voids between the strands. A micrograph is made when validating a new applicator or terminal, during customer audits and in case of complaints.
4. Crimp force monitoring (CFM)
A sensor in the press measures the force curve of every crimp and compares it with a reference. The system detects, among other things, missing strands in the crimp, insulation in the conductor crimp area or a missing terminal. This is a check of every piece during production – it complements sample measurements but does not replace them.
5. Calibration and repeatability
The results are reliable only if the measuring equipment is in good order: micrometers and testers should have calibration certificates, and press force is worth checking periodically with a calibration gauge. For automotive requirements, process capability (e.g. CMK / Cpk) for crimp height is also assessed.